Insulation Calculator — Rolls, Batts, Bags and R-Value

Insulation Calculator — Rolls, Batts, Bags and R-Value

Estimate insulation area, required thickness, rolls, batts, boards or bags, R-value or RSI, waste allowance and material cost in metric or imperial units.

Calculator

Advanced settings

Results

Imperial
Packages, rolls or bags to buy0 pcs
Insulation coverage to order0 ft²
Required or entered thickness0 in
Estimated combined thermal resistance0 h·ft²·°F/BTU (R)
Net insulation area0 ft²
Gross surface area0 ft²
Openings deducted0 ft²
Additional allowance area0 ft²
Thermal resistance added by the new layer0 h·ft²·°F/BTU (R)
Target value used0 h·ft²·°F/BTU (R)
Geometric insulation volume0 ft³
Total purchased coverage0 ft²
Estimated coverage left0 ft²
How package coverage was applied0
Checks before relying on the estimate0
Result guidance0

This calculator handles two connected tasks: estimating insulation thickness from a target R-value or RSI and converting the project area into complete rolls, batt packs, board packs, kits or bags.

Start with the net area that will actually be insulated

Enter a known area, calculate one or more identical rectangular surfaces, or calculate the four walls of a rectangular room. Doors, windows and other sections that will not receive insulation can be deducted separately.

Three ways to enter the project size

ModeInputsUseful for
Known areaOne value in ft² or m²Plans, quotations or several zones already totalled
Rectangular surfacesLength, width and quantityRoof slopes, ceiling sections, wall panels or floor areas
Four room wallsRoom length, width and wall heightA simple rectangular room

R-value and RSI describe resistance to heat flow

R-value is the familiar US measure, while RSI in m²·K/W is widely used with metric specifications. The unit switch converts the target, existing resistance and product resistance rate, allowing the same calculation to be read in US customary or metric units.

The calculator does not choose a code-required R-value or RSI. The required value depends on the country, state, province or territory, climate zone, building element, project type and locally adopted rules.

Use the thermal resistance of the exact product

Enter the product resistance per inch or per 25 mm from its label or technical data sheet. Products in the same broad material family can differ in density, formulation, tested performance and permitted installed thickness.

The target is R-30, the existing layer is R-11 and the new product provides R-3.5 per inch. How much additional thickness is needed?

Answer: The missing resistance is R-19. Estimated thickness is 19 ÷ 3.5 = 5.43 in, or about 138 mm.

Explanation: This estimates the insulation layer itself. Framing, fasteners, air spaces and thermal bridges can change the performance of the complete assembly.

Package coverage must match the selected thickness

Which coverage figure belongs in the form

Product formatEnterCheck
Rolls or battsCoverage of one roll or batt packThe thickness and stated R-value/RSI must match
Rigid boardsCombined board area in one packDo not confuse one board with the complete pack
Loose-fill or blown-in bagsMaximum net coverage per bag for the selected R-valueUse the correct row from the manufacturer's coverage chart
Spray foam or another kitArea covered by one kit at the required thicknessDo not use a headline coverage figure for a thinner application

Loose-fill coverage per bag is not constant. It changes with installed thickness, density, settling and target R-value, so a generic square-feet-per-bag figure is not enough.

Why the package quantity rounds up

The selected allowance is added to the net area before the result is divided by package coverage. Because partial unopened retail rolls, packs or bags are not normally available, the purchase quantity is rounded upward.

A project covers 500 ft², the allowance is 10%, and one package covers 100 ft². How many packages are needed?

Answer: The adjusted area is 550 ft². The mathematical result of 5.5 rounds up to 6 packages, providing 600 ft² of purchased coverage.

Explanation: The estimated 50 ft² remainder may consist of separate cuts rather than one reusable piece.

Insulation-layer R-value is not the whole wall or roof result

For planning, the calculator adds the entered existing resistance and the new insulation layer. It does not model wood or metal framing, headers, fixings, joints, moisture, air leakage or thermal bridges, so it is not a complete whole-assembly U-value calculation.

Terminology changes between markets

Common US and international wording

US-oriented wordingOther wording you may seeMeaning here
AtticLoft or roof spaceThe space below or within the roof
BattInsulation slab, segment or matA pre-cut piece intended to fit a defined space
Loose-fill / blown-inBlown fibre or granulated insulationMaterial installed from bags at a specified density and depth
R-valueRSI or thermal resistanceResistance to heat flow in different unit systems
Vapor retarderVapour control layerA separate moisture-control component when the assembly requires one

Before installation, check fire safety, ventilation, airtightness, vapor or vapour control, moisture management, clearances around wiring and recessed lights, and the current instructions for the selected product and assembly.

Read how HomDera handles assumptions, unit conversion, rounding and calculator limitations.